人人妻人人澡人人爽一区,国产综合99无码视频,日韩无码 久久综合,无码一区二区五区蜜桃,精品无码国产一区二区三区AVw,久久国语露脸国产精品电影

青島科迪博電子科技有限公司
免費(fèi)會(huì)員

當(dāng)前位置:青島科迪博電子科技有限公司>>產(chǎn)品中心>> 取樣管線 便攜式取樣管 儀表電磁閥

取樣管線 便攜式取樣管 儀表電磁閥

參  考  價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)

產(chǎn)品型號(hào)

品       牌

廠商性質(zhì)經(jīng)銷商

所  在  地青島市

聯(lián)系方式:張先生查看聯(lián)系方式

更新時(shí)間:2024-10-17 13:05:34瀏覽次數(shù):106次

聯(lián)系我時(shí),請(qǐng)告知來(lái)自 儀表網(wǎng)
取樣管線 便攜式取樣管

Typ PSP 4M4/6

Completely assembled fitting to the PSP4000-H

Including power supply cable for the PSP4000-H

Robust construction

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series PSP 4M4/6 are used in portable gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).


Typ PSP-W 4M4/6

Completely assembled fitting to the PSP4000-H

Including power supply cable for the PSP4000-H

Robust construction

Small outside diameter

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series PSP-W 4M4/6 are used in portable gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).

Typ 3-S

Applicable for outside installation

Different diameters

Different temperature ranges

Completely assembled

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series 3-N/M-S may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).

Typ 3

Robust construction

Applicable for outside installation

Different diameters

Different temperature ranges

Completely assembled

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series 3-N/M/H may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).

Typ 4-S

Applicable for outside installation

Different diameters

Different temperature ranges

Completely assembled

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series 4-N/M-S may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).

Typ 4

Robust construction

Applicable for outside installation

Different diameters

Different temperature ranges

Completely assembled

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series 4-N/M/H may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).

Typ 5

Robust construction

Applicable for outside installation

Different diameters

Different temperature ranges

Completely assembled

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series 5-N/M/H may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).

Typ 3Ex

Robust construction

Applicable for outside installation

Different diameters

Different temperature ranges

Completely assembled

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series 3-N/M/H EX may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).

Typ 4 EX

Robust construction

Applicable for outside installation

Different diameters

Different temperature ranges

Completely assembled

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series 4-N/M/H EX may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).

Typ 5 EX

Robust construction

Applicable for outside installation

Different diameters

Different temperature ranges

Completely assembled

Length as desired

Application:

The electrically heated, „plug-in system“, M&C - sample lines series 5-N/M/H EX may be used with advantage in gas analysis systems. Their application helps avoid errors and acts as frost protection during transport of the sample gas from the sample point to the gas conditioning system or directly to a heated analyser (above dew point).

Typ 3

Self-regulated without temperature controller

Robust construction

Applicable for outside installation

Different diametes

Different holding temperatures

Completely assembled

Yard ware treated externally

Length as desired

Application:

The electrically heated self regulated M&C-sample lines 3/ are used in gas analysis technique for transportation of the sample gas from the sample point to the gas conditioning system. They prevent measurement faults in the lower temperature ranges from +5°C to +100°C and protect the system against freeze. A temperature monitoring of the total heated line is not possible due to the function as parallel heater band.

Typ 4

Self-regulated without temperature controller

Robust construction

Applicable for outside installation

Different diameters

Different holding temperatures

Completely assembled

Yard ware treated externally

Length as desired

Application:

The electrically heated self regulated M&C-sample lines 4/ are used in gas analysis technique for transportation of the sample gas from the sample point to the gas conditioning system. They prevent measurement faults in the lower temperature ranges from +5°C to +100°C and protect the system against freeze. A temperature monitoring of the total heated line is not possible due to the function as parallel heater band.

Typ 5

Self-regulated without temperature controller

Robust construction

Applicable for outside installation

Different diameters

Different holding temperatures

Completely assembled

Yard ware treated externally

Length as desired

Application:

The electrically heated self regulated M&C-sample lines 5/ are used in gas analysis technique for transportation of the sample gas from the sample point to the gas conditioning system. They prevent measurement faults in the lower temperature ranges from +5°C to +100°C and protect the system against freeze. A temperature monitoring of the total heated line is not possible due to the function as parallel heater band.

Typ 3EX

Self-regulated without temperature controller

Robust construction

Applicable for outside installation

Different diameters

Different holding temperatures

Completely assembled

Yard ware treated externally

Length as desired

Application:

The electrically heated self regulated M&C-sample lines 3/../Ex are used in gas analysis technique for transportation of the sample gas from the sample point to the gas conditioning system. They prevent measurement faults in the lower temperature ranges from +5°C to +100°C and protect the system against freeze. A temperature monitoring of the total heated line is not possible due to the function as parallel heater band.

Typ 4EX

Self-regulated without temperature controller

Robust construction

Applicable for outside installation

Different diameters

Different holding temperatures

Completely assembled

Yard ware treated externally

Length as desired

Application:

The electrically heated self regulated M&C-sample lines 4/../Ex are used in gas analysis technique for transportation of the sample gas from the sample point to the gas conditioning system. They prevent measurement faults in the lower temperature ranges from +5°C to +100°C and protect the system against freeze. A temperature monitoring of the total heated line is not possible due to the function as parallel heater band.

Typ 5EX

Self-regulated without temperature controller

Robust construction

Applicable for outside installation

Different diameters

Different holding temperatures

Completely assembled

Yard ware treated externally

Length as desired

Application:

The electrically heated self regulated M&C-sample lines 5/../Ex are used in gas analysis technique for transportation of the sample gas from the sample point to the gas conditioning system. They prevent measurement faults in the lower temperature ranges from +5°C to +100°C and protect the system against freeze. A temperature monitoring of the total heated line is not possible due to the function as parallel heater band.