SP2000-H/DILBasedonprobeSP2000H/

SP2000-H/DIL

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


SP2300-H/DIL

Based on probe SP2300H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

Material: PTFE, FPM, ceramic

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2300H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


SP2000-H320/DIL

Based on probe SP2000H/....

Electrically heated up to 320°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


SP2000-H/DIL-VA

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With integrated ball valve at the probe inlet

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas.


SP2000-H/DIL-B

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time.


SP2000-H320/DIL-B

Based on probe SP2000H/....

Electrically heated up to 320°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time.


SP2000-H/DIL-BR

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time and integrated gas recirculation

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time and the integrated gas recirculation allows to remove the sample gas back into the process.

SP2000-H320/DIL-BR

Based on probe SP2000H/....

Electrically heated up to 320°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time and integrated gas recirculation

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time and the integrated gas recirculation allows to remove the sample gas back into the process.

SP2000-H/DIL-VA-B

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With integrated ball valve at the probe inlet and bypass injector to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas and the additional bypass injector minimizes the response time.


SP2000-H/DIL-VA-BV

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With heated hand-operated ball valve at the sample inlet and bypass connection with needle valve in order to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas and the additional bypass injector with needle valve minimizes the response time.


SP2006-H/DIL-B/2x/F

Based on probe SP2000-H/...

Electrically heated up to 180 °C or 280 °C

NEMA 4, FRP housing

External heated critical orifice with additional safety filter

Including a dilution gas pre-heater

No dew point problems

Dilution ratios from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Changing of dilution and bypass block without any tools within a few minutes

No disconnection of any tubes or hoses for changing of dilution or bypass block

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.


SP2006-H/DIL-BR/2x/F

Based on probe SP2000-H/...

Electrically heated up to 180 °C or 280 °C

NEMA 4, FRP housing

External heated critical orifice with additional safety filter

Including a dilution gas pre-heater

No dew point problems

Dilution ratios from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Changing of dilution and bypass block without any tools within a few minutes

No disconnection of any tubes or hoses for changing of dilution or bypass block

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.


SP2006-H/DIL/2x/F

Based on probe SP2000-H/...

Electrically heated up to 180 °C or 280 °C

NEMA 4, FRP housing

External heated critical orifice with additional safety filter

Including a dilution gas pre-heater

No dew point problems

Dilution ratios from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Changing of dilution and bypass block without any tools within a few minutes

No disconnection of any tubes or hoses for changing of dilution or bypass block

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
在線留言
鄂托克前旗| 齐齐哈尔市| 靖州| 鸡西市| 勐海县| 松滋市| 卢湾区| 洪洞县| 锡林浩特市| 杨浦区| 隆子县| 新沂市| 广宗县| 巴楚县| 乡城县| 华容县| 锦州市| 繁昌县|