主要參數
1、交流電壓輸出
0~250V連續(xù)可調,zui大輸出容量600VA,過量程保護260V,誤差為±1%。
2、交流電流輸出
0~50A,0~100A連續(xù)可調,誤差為±1%。
0~50A時,開路電壓5V。
0~100A時,開路電壓10V。過載保護動作電流120A。
3、直流電壓輸出
0~250V連續(xù)可調,zui大電流2A,過量程保護260V,過載保護動作電流2.1A±5%。誤差為±1%
4、直流電流輸出
0~200mA 0~5 A連續(xù)可調,誤差為±1%。
0~200mA時,開路電壓48V,過載保護動作電流230mA。
0~5A時,開路電壓24V,過載保護動作電流5.2A。
5、直流電壓固定輸出
單獨輸出110V或220V時,電流可達2.5A,但和交流電壓電流,直流電壓同時輸出時。其總容量不能超過600VA。
6、數字毫秒表
zui大量程:999秒
分辨率:0.1毫秒
精 度:0.1%±1個字
7、儀表準確度采用四位半A/D轉換,精度0.1%讀數±1個字
8、整機測量精度:≤1%
9、體積:480mm×320mm×160mm
10、重量:18Kg
The main characteristics of testers
1.As the single-phase relay tester adopting microcomputer control, therefore there are only 16 touch switches on the panel, that can complete varies of testing functions, change the old-fashioned relay protect tester which must turn off the power switch and toggle switch to convert power supply type, easy to operate. The single-phase relay tester set self-checking and error function, which convenient for inspection and maintenance.
2.The single-phase relay tester set comprehensive self-checking and self-protection function, which can make immediay self-checking after booting, in the process of overload and over-range measuring, the protection circuit will quickly cut off output, and will give a sounding and light alarm to reduce the unnecessary losses due to misuse greatly.
3.The single phase relay tester with high inligence, just press a button, that you can measure all the general electric relay parameters, automatically printing, and allowing you free from the tedious testing operation.
4.The device display screen unit, clearly reflect of operating status will show on the display screen.
5.The printed data will all be displayed in English characters, such as "pull-in voltage", "disconnect voltage", "normally open pull-in time" and so on.
The parameters of the products
1. AC voltage output
0 ~ 250V continuously adjustable , the maximum output capacity is 600VA, over- range protection is 260V, error of ± 1%.
2.AC current output
0 ~ 50A, 0 ~ 100A continuously adjustable error of ±1%.
0 ~ 50A , the open circuit voltage is 5V.
0 ~ 100A , the open circuit voltage is 10V. Overload operating current is 120A.
3.DC voltage output
0 ~ 250V continuously adjustable , the maximum current is 2A, over- range protection is 260V, overload trip current is 2.1A ± 5%. Error of ± 1%
4.DC current output
0 ~ 200mA 0 ~ 5 A continuously adjustable error of ± 1%.
0 ~ 200mA , the open circuit voltage is 48V, overload operating current is 230mA.
0 ~ 5A , the open circuit voltage is 24V, overload protective current is 5.2A
5.DC voltage fixed output
The current will up to 2.5A, when the separate output is 110V or 220V. However when AC voltage current and DC voltage current output simultaneously, the total capacity can not exceed 600VA.
6.Digital millisecond meter
Maximum Range: 999 seconds
Resolution: 0.1 millisecond
Accuracy : 0.1% ± 1 word
7.The device adopts four and half- meter A / D conversion , the accuracy is 0.1 % and reading ± 1 word.
8.Accuracy of whole measurement: ≤1%
9.Volume : 480mm×320mm×160mm
10.Weight : 18Kg