CO measurement
Range: 0...500 ppm
0...1,500 ppm (briefly)
Accuracy: ±5 ppm, 0...99 ppm
±5%, 100...499 ppm
±10%, 500...1,500 ppm
Setting time t90: < 30 s
Display: 3 1/2 figure LCD, CO
dep. puls-width modulated signal tone
Storage temp.: -20...50 °C
Work temp.: 10...40 °C
Supply: 9 V block battery
Size: 12 x 6 x 2.5 cm
Weight: 230 g
Applications
- Measurement of CO concentration in the ambient air
- control of gas leakages on firings
Comes with
Instrument with flex holder, leather cover and battery