5EH-800F smart buoy level transmitter is based on Archimedes principle of law and the magnetic coupling design from the liquid level measuring instruments, meters can be measured liquid level, industry position and density of the upper and lower limit alarm signal output is responsible for . Dedicated to measure the pressure vessellevel, consists of four basic components: float, spring, magnet room and indicators.
Technical parameters
Range :300-6000mm Accuracy: 1.5
Standard: 4.0MPa Special: Maximum 25MPa
Ambient temperature: -25 ℃ -65 ℃ medium temperature: -40 ℃ -100 ℃ special type: -40 ℃ -200 ℃
Medium Density :0.45-3 .0g/cm3 proof requirements: An explosion-proof, explosion-proof form, see transmitter instructions
Explosion isolation, explosion-proof mark: Exd Ⅱ CT6 protection class: IP65
Flange: Standard: the float GB / T 9119-2000 DN50, PN4.0 outside the buoys GB / T 9119 - 2000 DN40, PN4.0
Specificity: other arbitrary standard flange
Wetted Materials: 1Cr18Ni9Ti, 0Cr18Ni12Mo2Ti