9EG-500S inligent electromagnetic flowmeter is based on the principle of electromagnetic induction Ferrari and special function of magnetic field technology developed a good stability and high precision inligent electromagnetic flowmeter. For conducting closed pipe flow measurement of liquids and slurries, such as chemical water, process water, water purification, sewage, various chemical salt solution, slurry, pulp, paper pulp and liquid foods. Widely used in metallurgy, paper making, water treatment, chemical industry, light industry, textile, power and mining industries.
KENER numerical performance of their products to ensure stable, reliable and energy saving. No error values ??given is the same type of instruments from a range of the average performance values ??obtained.
Technical parameters
Measurement of fluid: conductive liquid, slurry Flange Material: Carbon steel
Conductivity: ≥ 5S/cm output signal: 4-20mA standard power frequency :0-1kHz
Velocity range :0.5-10m / s extended-range :0.1-15m / s Communication: RS-485
Accuracy: <500mm ± 0.5% ≥ 500mm ± 0.2% (normal flow) alarm: normally open
Repeatability: <500mm ± 0.3% ≥ 500mm ± 0.1% (normal flow) Working power: DC2410VA/AC220V10VA
Working pressure: ≤ 0.6MPa (DN1100-1200) working environment:
≤ 1.0MPa (DN200-1000) Temperature: -45 ℃ -0 ℃
≤ 1.6MPa (DN100-150) operation:
≤ 4.0MPa (DN6-80) Storage: 20 ℃ -55 ℃
Fluid temperature: E-class <80 ℃ H-level <120 ℃ Operating humidity: Non-condensing
Protection class: IP65 IP68 0-10 ℃ 10-30 ℃: 95% 30-40 ℃: 75% 40-45 ℃: 45%
Electrode material: stainless steel tantalum titanium platinum iridium Harrington storage -20-55 ℃: Non-condensing
Altitude Operating: 2000m Storage: 9000m
Lining Materials: Natural rubber, neoprene rubber, polyurethane rubber acid-resistant Teflon
Vibration: <2g Impact <20g EX: Explosion